Dell PowerEdge R910 Informações Técnicas

Consulte online ou descarregue Informações Técnicas para Barebones PC/estação de trabalho Dell PowerEdge R910. Dell PowerEdge R910 System information Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 78
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - PowerEdge R910

Dell PowerEdge R910 Technical Guide

Página 2

Dell Dell PowerEdge R910 Technical Guide 10 2 New Technologies 2.1 Overview The PowerEdge R910 uses a number of new technologies:  Intel 7

Página 3 - Table of Contents

Dell Dell PowerEdge R910 Technical Guide 11 2.2.2 Internal Dual SD Module (IDSM) The PowerEdge R910 also offers a second internal USB port de

Página 4

Dell Dell PowerEdge R910 Technical Guide 12 3 System Information Table 2. Summary of R910 features Feature Details Processor Intel® Xeon® Proc

Página 5 - Figures

Dell Dell PowerEdge R910 Technical Guide 13 Feature Details Broadcom® 57711 (2 ports x 10Gb SFP+) and Broadcom® 5709c (2 ports x 1GbE Base-T Cop

Página 6

Dell Dell PowerEdge R910 Technical Guide 14 Feature Details Novell® SUSE® Linux® Enterprise Server Red Hat® Enterprise Linux® For more informat

Página 7 - 1 Product Comparison

Dell Dell PowerEdge R910 Technical Guide 15 4 Mechanical 4.1 Chassis Description The PowerEdge R910 fits in a rack mount 4U chassis. The R910

Página 8

Dell Dell PowerEdge R910 Technical Guide 16 Figure 3. R910 Rear View 4.2 Dimensions and Weight The R910 weight with maximum configuration is

Página 9

Dell Dell PowerEdge R910 Technical Guide 17 Xa (Width w/ Rack Latches) Xb (Width w/o Rack Latches) Y (Height) Za (Depth w/ bezel) Za (Depth w/

Página 10 - 2 New Technologies

Dell Dell PowerEdge R910 Technical Guide 18 Figure 5. Front Panel View of R910 The following components and connectors are located on the fr

Página 11 - 2.2.3 10Gb Embedded NIC

Dell Dell PowerEdge R910 Technical Guide 19 The LCD panel is a graphics display controlled by the iDRAC6. Error codes can be sent to the display

Página 12 - 3 System Information

Dell Dell PowerEdge R910 Technical Guide 2 This document is for informational purposes only. Dell reserves the right to make

Página 13

Dell Dell PowerEdge R910 Technical Guide 20  Active ID Cable Management Arm (CMA) external led jack  (2) USB ports  (Optional) RJ-45 iDRA

Página 14

Dell Dell PowerEdge R910 Technical Guide 21 4.7 Internal Chassis View Figure 10. R910 Internal View 4.8 Rails and Cable Management ReadyRailsT

Página 15 - 4 Mechanical

Dell Dell PowerEdge R910 Technical Guide 22 Figure 11. R910 Fan Cage

Página 16 - 4.2 Dimensions and Weight

Dell Dell PowerEdge R910 Technical Guide 23 4.10 Cabling CPU1CPU2CPU3CPU4BATSLOT1IOH1IOH2ICH10iDRACSLOT2SLOT3SLOT4SLOT5SLOT6SLOT7IO RISERSTORAG

Página 17 - Figure 4. R910 Dimensions

Dell Dell PowerEdge R910 Technical Guide 24 4.11 Security 4.11.1 Cover Latch A tooled latch is integrated in the side cover to secure it to th

Página 18

Dell Dell PowerEdge R910 Technical Guide 25 4.11.3 Hard Drive The front bezel of the system contains a lock. A locked bezel secures the system

Página 19

Dell Dell PowerEdge R910 Technical Guide 26 Figure 15. USB Key Location 4.13 Battery A replaceable coin cell CR2032 3V battery is mounted on t

Página 20 - 4.6 NIC Indicators

Dell Dell PowerEdge R910 Technical Guide 27 Figure 16. Coin Cell Battery on Motherboard 4.14 Field Replaceable Units (FRU) The planar cont

Página 21 - 4.9 Fans

Dell Dell PowerEdge R910 Technical Guide 28 5 Electrical 5.1 Clock Circuitry System clock circuitry is based on Intel CK410B+ synthesiz

Página 22

Dell Dell PowerEdge R910 Technical Guide 29 6 Power, Thermal, Acoustic The PowerEdge R910 achieves enhanced power efficiency by implementing t

Página 23 - BASEBOARD

Dell Dell PowerEdge R910 Technical Guide 3 Table of Contents 1 Product Comparison ...

Página 24 - 4.11 Security

Dell Dell PowerEdge R910 Technical Guide 30 The power supply bay is designed to prevent unsupported power supplies from being installed. Mixing

Página 25 - 4.12 USB Key

Dell Dell PowerEdge R910 Technical Guide 31 Table 4. Power Supply Specifications AC Power supply (per power supply) Wattage 1100 W (High Output

Página 26 - 4.13 Battery

Dell Dell PowerEdge R910 Technical Guide 32 Table 5. Operating/Non-Operating (Storage) Requirements Temperature Operating 10o to 35 o C (50 o t

Página 27

Dell Dell PowerEdge R910 Technical Guide 33 Table 6. Acoustics of the PowerEdge R910 Typical Configuration(1) @ 23 ± 2 °C Operating Mode LWA-UL

Página 28 - 5 Electrical

Dell Dell PowerEdge R910 Technical Guide 34 Table 7. Configuration Corresponding to Acoustical Data Presented Component Description Qty Process

Página 29 - 6 Power, Thermal, Acoustic

Dell Dell PowerEdge R910 Technical Guide 35 7 Processors 7.1 Overview The Intel Xeon processor 7500 series is designed specifically

Página 30

Dell Dell PowerEdge R910 Technical Guide 36  Intel 64 Technology  Intel VT-x and VT-d Technology for virtualization support  Enhanced Inte

Página 31 - 6.3 Thermal

Dell Dell PowerEdge R910 Technical Guide 37 8 Memory 8.1 Overview The PowerEdge R910 uses DDR3 memory providing a high-performance, high-speed

Página 32 - 6.4 Acoustics

Dell Dell PowerEdge R910 Technical Guide 38 Figure 18. PowerEdge R910 DIMM Naming and Numbering

Página 33

Dell Dell PowerEdge R910 Technical Guide 39 8.2 Slots/Risers R910 has 8 memory risers; each memory riser has 8 DIMM slots. So there are a total

Página 34

Dell Dell PowerEdge R910 Technical Guide 4 7.2 Features ...

Página 35 - 7 Processors

Dell Dell PowerEdge R910 Technical Guide 40 8.6 Mirroring For mirroring, the PowerEdge R910 supports 2P/4P configurations for 64GB and larger on

Página 36 - 7.4 Processor Configurations

Dell Dell PowerEdge R910 Technical Guide 41 9 Chipset The R910 system-board incorporates the Intel 7500 chipset (Boxboro‐EX) for I/O

Página 37 - 8 Memory

Dell Dell PowerEdge R910 Technical Guide 42 • Platform Environmental Control Interface (PECI) • Intel Dynamic Power Mode Manager • I/O interr

Página 38

Dell Dell PowerEdge R910 Technical Guide 43 10 BIOS 10.1 Overview The R910 BIOS is based on the Dell BIOS core, and supports the following fea

Página 39 - 8.5 Sparing

Dell Dell PowerEdge R910 Technical Guide 44 11 Embedded NICs/LAN on Motherboard (LOM) R910 supports two options for Embedded NICs (I/O riser car

Página 40 - 8.8 Supported Configurations

Dell Dell PowerEdge R910 Technical Guide 45 12 I/O Slots 12.1 Overview The R910 planar provides seven PCI Express expansion slots as the base. T

Página 41 - 9 Chipset

Dell Dell PowerEdge R910 Technical Guide 46 12.2 Quantities and Priorities See Expansion Cards and Expansion Card Riser in the Hardware Owner’

Página 42 - 9.6 PCI Express Connectors

Dell Dell PowerEdge R910 Technical Guide 47 13 Storage 13.1 Overview The R910 system supports up to sixteen 2.5” hard disk drives.  Support f

Página 43 - 10 BIOS

Dell Dell PowerEdge R910 Technical Guide 48 POWERSAS A Figure 20. 2.5” x4 Backplane 13.2.2 2.5” x16 Backplane The 16-drives 2.5‖ HDD backpla

Página 44

Dell Dell PowerEdge R910 Technical Guide 49 13.3 Flash BIOS Memory A Flash EEPROM resides on the SPI Bus for BIOS and configuration storage. A 1

Página 45 - 12 I/O Slots

Dell Dell PowerEdge R910 Technical Guide 5 16.1 Overview ...

Página 46 - 12.3 PCI Card Information

Dell Dell PowerEdge R910 Technical Guide 50 13.5 RAID Configurations Table 11. RAID Configurations Configuration Type Configs Description Non

Página 47 - 13 Storage

Dell Dell PowerEdge R910 Technical Guide 51 Configuration Type Configs Description Mixed SATA SSD / SAS HDD 2.5” Drives x4 Backplane x16 Backpla

Página 48 - 13.2.2 2.5” x16 Backplane

Dell Dell PowerEdge R910 Technical Guide 52 13.6 Storage Controllers 13.6.1 PERC H200 The PERC H200 integrated HBA is a SAS 2.0 6Gb native PCIe

Página 49 - 13.4 Drives

Dell Dell PowerEdge R910 Technical Guide 53 13.6.4 Storage Card Support Matrix Table 12. Storage Card Support Matrix SKU Product Usage Powe

Página 50 - 13.5 RAID Configurations

Dell Dell PowerEdge R910 Technical Guide 54 13.7 LED Indicators Each hard drive carrier has two LED indicators visible from the front of the sys

Página 51

Dell Dell PowerEdge R910 Technical Guide 55 14 Video The R910 Integrated Dell Remote Access Controller 6 (iDRAC6) incorporates an in

Página 52 - 13.6 Storage Controllers

Dell Dell PowerEdge R910 Technical Guide 56 15 Audio R910 does not support speakers or audio output.

Página 53

Dell Dell PowerEdge R910 Technical Guide 57 16 Rack Information 16.1 Overview The ReadyRails™ sliding rail system for the R910 provides tool-les

Página 54 - 13.8 Optical Drives

Dell Dell PowerEdge R910 Technical Guide 58 *Adapter brackets are available from RackSolutions that allow the R910 sliding rails to mount in t

Página 55 - 14 Video

Dell Dell PowerEdge R910 Technical Guide 59 Figure 24. R910 Mounted in the B2 Sliding Rails The R910 CMA can be mounted to either side of the

Página 56 - 15 Audio

Dell Dell PowerEdge R910 Technical Guide 6 Figure 7. Back Panel View ...

Página 57 - 16 Rack Information

Dell Dell PowerEdge R910 Technical Guide 60 17 Operating Systems For the most up-to-date information, see the Operating System Support Matrix f

Página 58 - 16.4 Rack View

Dell Dell PowerEdge R910 Technical Guide 61 18 Virtualization The following virtualization software is supported:  Microsoft Windows Server 20

Página 59

Dell Dell PowerEdge R910 Technical Guide 62 19 Systems Management 19.1 Overview/Description Dell aims on delivering open, flexible, and integra

Página 60 - 17 Operating Systems

Dell Dell PowerEdge R910 Technical Guide 63 19.3 Embedded Server Management The PowerEdge R910 implements circuitry for the next generation of E

Página 61 - 18 Virtualization

Dell Dell PowerEdge R910 Technical Guide 64 19.5 Optional iDRAC Express The optional iDRAC Express is the first tier of iDRAC6 upgrades. In addi

Página 62 - 19 Systems Management

Dell Dell PowerEdge R910 Technical Guide 65 Feature BMC iDRAC 6 Express iDRAC6 Enterprise vFlash Media VLAN Tagging     IPv6  

Página 63 - • vFlash

Dell Dell PowerEdge R910 Technical Guide 66 Feature BMC iDRAC 6 Express iDRAC6 Enterprise vFlash Media System Event Log     RAC Log

Página 64 - 19.6 iDRAC6 Enterprise

Dell Dell PowerEdge R910 Technical Guide 67 20 Peripherals 20.1 USB peripherals PE R910 supports the following USB devices:  DVD (bootable; r

Página 65

Dell Dell PowerEdge R910 Technical Guide 68 Appendix A. Regulatory Certifications Table 19. Standards Compliance Standard URL for Information

Página 66

Dell Dell PowerEdge R910 Technical Guide 69 Standard URL for Information and Specifications Windows Logo Windows Logo Program System and Device

Página 67 - 20 Peripherals

1 Product Comparison 1.1 Overview of PowerEdge R910 Benefits The Dell™ PowerEdge™ R910 provides performance and reliability in a scalable 4U, four-so

Página 68

Dell Dell PowerEdge R910 Technical Guide 70 Appendix B. R910 Volatility Table Table 20. R910 Volatility Server BIOS Memory (SPI Flash, IC) Siz

Página 69

Dell Dell PowerEdge R910 Technical Guide 71 executable containing firmware file and loader How is this memory write protected? Software write pr

Página 70 - Table 20. R910 Volatility

Dell Dell PowerEdge R910 Technical Guide 72 Type [e.g., Flash PROM, EEPROM]: EEPROM Can user programs or operating system write data to it durin

Página 71

Dell Dell PowerEdge R910 Technical Guide 73 How is data input to this memory? Data is pre-programmed by vendor. Keys are updated using TPM enabl

Página 72

Dell Dell PowerEdge R910 Technical Guide 74 Type [e.g., Flash PROM, EEPROM]: Serial EEPROM Can user programs or operating system write data to i

Página 73

Dell Dell PowerEdge R910 Technical Guide 75 enabled in the case of a power loss. How is data input to this memory? FRU/CPLD data is preprogramme

Página 74

Dell Dell PowerEdge R910 Technical Guide 76 How is data input to this memory? Loading flash memory requires a vendor-provided firmware file and

Página 75

Dell Dell PowerEdge R910 Technical Guide 77 number of PSUs installed. Dell Internal Dual SD Module (IDSM) microcontroller flash (if present) Siz

Página 76

Dell Dell PowerEdge R910 Technical Guide 78 vFlash for iDRAC Enterprise Size: Multiple Type [e.g., Flash PROM, EEPROM]: Secure Digital NAND Flas

Página 77

Dell Dell PowerEdge R910 Technical Guide 8 1.2 Comparison of PowerEdge R910 to PowerEdge R900 The Dell™ PowerEdge™ R910 is Dell’s 11th generatio

Página 78

Dell Dell PowerEdge R910 Technical Guide 9 Feature/Spec PowerEdge R910 PowerEdge R900 (predecessor) x8, 1 x16) Optional: 10 PCIe Gen2 (6 x4, 4 x

Comentários a estes Manuais

Sem comentários