Memory Group 361
Table 15-6. Physical Memory Configuration Redundant Settings
Variable Name:
DellPhysicalMemoryConfigRedundantSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no redundant memory settings enabled.
unknown(1) Redundant settings are unknown.
The following redundant settings are mutually exclusive:
spareEnabled(2) Spare redundant memory feature is enabled.
mirrorEnabled(4) Mirror redundant memory feature is enabled.
raidEnabled(8) RAID redundant memory feature is enabled.
Table 15-7. Physical Memory Logging Capabilities
Variable Name:
DellPhysicalMemoryLoggingCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no logging capabilities.
unknown Capabilities(1) Logging capabilities are unknown.
The logging capabilities are:
enableCapable(2) Logging enable/disable using Simple Network
Management Protocol (SNMP) is supported.