Known problems and limitations
EMC AX4-5 Series Integrated Management Software Release Notes
Known problems and limitations
This section identifies outstanding issues with this version, and
important warnings associated with the connectivity and compatibility
of this product. It also provides useful recommendations.
Visit the EMC Powerlink
®
Issue Tracker website at
http://Powerlink.EMC.com for the most recent updates and information
on previous FLARE versions.
Known problems in version 02.23.050.5.709
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
A single-SP panic with
bugcheck code (0x0A) occurs
after a migration session’s
owning SP reboots.
199000
Frequency of occurrence
:
Rarely under a specific set of
circumstances.
Severity
:
Medium
When a migration session
is running and its owning
SP is rebooted, after the
SP is back, it may panic.
After the SP recovers from
the panic, migration
continues to progress and
finishes.
None. After the system
recovers from the SP
panic, the migration
session will resume its
progress and finish.
Exists in versions
:
02.23.050.5.703
02.23.050.5.705
02.23.050.5.707
02.23.050.5.709
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
System fails to boot during
image from flash operation.
190842
Frequency of occurrence
:
Rarely under a specific set of
circumstances.
Severity
:
High
The first time the storage
system is powered up, it
does not boot. This occurs
only in systems that are
configured to image from
flash the first time they are
booted.
Knowledgebase solution
:
emc181529
Power-cycle the entire
storage system.
Exists in versions
:
02.23.050.5.703
02.23.050.5.705
02.23.050.5.707
02.23.050.5.709
Comentários a estes Manuais