Dell D630 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Pianos digitais Dell D630. Dell D630 Administrator's Guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Dell Systems Management Administrator's Guide
Notes, Notices, and Cautions
Information in this document is subject to change without notice.
©2007DellInc.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Intel Corporation is a contributing source of content in this document.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.; Intel and iAMT are registered trademarks of Intel Corporation; Microsoft and Windows are either
trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
October 2007 Rev. A00
About Intel® Active Management Technology
Deployment
Intel AMT Setup and Configuration Overview
Using the Intel AMT WebGUI
Intel Management Engine BIOS Extension (MEBx)
Redirecting Serial and IDE Communications
Provisioning: Setup and Configuration Completion
Troubleshooting
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Vista de página 0
1 2 3 4 5 6 ... 68 69

Resumo do Conteúdo

Página 1 - Notes, Notices, and Cautions

Dell™ Systems Management Administrator's Guide  Notes, Notices, and Cautions Information in this document is subject to change without notice.

Página 2 - Deployment

This allows you to select between small business and enterprise mode. Enterprise mode may have different security settings than small business mode. B

Página 3 - MEBx Overview

l Username and Password – DISABLED** / ENABLED This option provides the user authentication for SOL/IDER session. If the Kerberos protocol is used,

Página 4 - Intel ME State Control

Idle Timeout Use this setting to define the ME WoL idle timeout. When this timer expires, the ME enters a low-power state. This timeout takes effect

Página 5

Save and exit MEBx and then boot the computer to the Microsoft®Windows®operating system. Intel AMT in Static Mode Settings Example The table below

Página 6 - LAN Controller

*Default setting **May cause Intel AMT partial unprovision 1 Intel ME Platform State Control is only changed for Management Engine (ME) troubleshootin

Página 7 - Intel ME Features Control

Back to Contents Page About Intel® Active Management Technology Dell™ Systems Management Administrator's Guide Intel® Active Management Technolo

Página 8 - Intel ME Power Control

Back to Contents Page Redirecting Serial and IDE Communications Dell™ Systems Management Administrator's Guide Intel® AMT makes it possible to r

Página 9 - Menu Options

Back to Contents Page Intel® AMT Setup and Configuration Overview Dell™ Systems Management Administrator's Guide Terms Setup and Configuration

Página 10 - SOL/IDE-R

Back to Contents Page Provisioning: Completing the Setup and Configuration Process Dell™ Systems Management Administrator's Guide Using a Confi

Página 11 - Set PRTC

Setup and Configuration Using a USB Storage Device 1. Format a USB device with the FAT16 file system and no volume label and then set it aside.

Página 12 - Idle Timeout

Back to Contents Page Deployment Dell™ Systems Management Administrator's Guide Once you are ready to deploy a computer to a user, plug the comp

Página 13 - MEBx Default Settings

5. Click the plus (+) to expand the Section 1. Provisioning section. 6. Click the plus (+) to expand the Basic Provisioning (without TLS) section.

Página 14

7. Select Step 1. Configure DNS. The notification server with an out-of-band management solution installed must be registered in DNS as "Provis

Página 15 - About Intel

The IP address for the ProvisionServer and Intel SCS are now visible. 9. Select Step 2. Discovery Capabilities.

Página 16 - IDE Redirection Overview

10. Verify that the setting is Enabled. If Disabled, click the checkbox next to Disabled and click Apply. 11. Select Step 3. View Intel AMT Capable

Página 17

Any Intel AMT capable computers on the network are visible in this list. 12. Select Step 4. Create Profile.

Página 18 - Using a USB Storage Device

13. Click the plus (+) to add a new profile. 14. On the General tab the administrator can modify the profile name, description, and password. The a

Página 19

15. The Network tab provides the option to enable ping responses, VLAN, WebUI, Serial over LAN, and IDE Redirection. If you are configuring Intel AM

Página 20

18. The Power Policy tab has configuration options to select the sleep states for Intel AMT and an Idle Timeout setting. It is recommended that Idle

Página 21

20. Select the icon with the arrow pointing out to Export Security Keys to USB Key. 21. Select the Generate keys before export radio button.

Página 22

22. Enter the number of keys to generate (depends on the number of computers that need to be provisioned). The default is 50. 23. The Intel ME defa

Página 23

Back to Contents Page Intel® Management Engine BIOS Extension (MEBx) Dell™ Systems Management Administrator's Guide Intel MEBx Overview Config

Página 24

24. Click Generate. Once the keys have been created, a link appears to the left of the Generate button. 25. Insert the previously formatted USB devi

Página 25

 c. Click Close in the Download complete dialog box. The setup.bin file is now visible in the drive explorer window. 27. Close the Export Security

Página 26

30. Press any key to continue with system boot... 31. Once complete, turn off the computer and move back to the management server. 32. Select Ste

Página 27

34. Select Step 7. Monitor Provisioning Process. The computers for which the keys were applied begin to appearing in the system list. At first the

Página 28

35. Select Step 8. Monitor Profile Assignments. The computers for which profiles were assigned appear in the list. Each computer is identified by t

Página 29

Once the computers are provisioned, they are visible under the Collections folder in All configured Intel AMT computers. Using MEBx Interface to Co

Página 30

Intel AMT Configuration sets up all other Intel AMT options not covered in Intel AMT Setup, such as enabling the computer for Serial-Over-LAN (SOL) or

Página 31

 3. Select Change Intel ME Password. Press <Enter>. Type the new password twice for verification. The new password must include the followin

Página 32

5. The following message appears: System resets after configuration change. Continue (Y/N). Press <y>. 6. Intel ME State Control is the ne

Página 33

7. Select Intel ME Firmware Local Update. Press <Enter>. 8. Select Always Open. Press <Enter>. The default setting for this option is D

Página 34

The new password must include the following elements: l Eight characters l One uppercase letter l One lowercase letter l A number l A special (non

Página 35

10. Manageability Feature Selection is the next option. This feature sets the platform management mode. The default setting is Intel AMT. Selectin

Página 36 - Enterprise Mode

12. Select Intel ME Power Control. Press <Enter>.  13. Intel ME ON in Host Sleep States is the next option. The default setting is Mobile:

Página 37

14. Select Return to Previous Menu. Press <Enter>. 15. Select Return to Previous Menu. Press <Enter>. 16. Exit the MEBx Setup and sa

Página 38

 4. Select Host Name. Press <Enter>. Then type in a unique name for this Intel AMT machine. Press <Enter>. Spaces are not accepted in

Página 39

 l [DHCP Enable] Disable DHCP (Y/N) Press <n>.  l Domain Name Type the domain name into the field.

Página 40

6. Select Provision Server from the menu. Press <Enter>. 7. Type the provisioning server IP in the Provisioning server address field and pr

Página 41

8. Type the port in the Port number field and press <ENTER>.  The following message appears: l [Intel (R) AMT 2.6 Mode] [Enterprise]

Página 42

 10. Select SOL/IDE-R. Press <Enter>. 11. The following messages appear, and require the response indicated in the following bulleted list

Página 43

 l User name & Password ¡ Select Enabled and then press <Enter>. This option allows you to add users and passwords from the WebGUI. If t

Página 44

l IDE Redirection Select Enabled and then press <Enter>. 12. Secure Firmware Update is the next option. The default setting is Enabled.

Página 45

When enabled, the ME State Control option lets you disable ME to isolate the ME computer from the main platform while debugging a field malfunction.

Página 46

13. Skip Set PRTC. 14. Idle Timeout is the next option. The default setting is 1. This timeout is applicable only when a WoL option is selected i

Página 47

  15. Select Return to Previous Menu. Press <Enter>. 16. Select Exit. Press <Enter>.

Página 48

17. The following message appears: Are you sure you want to exit? (Y/N): Press <y>. 18. The computer restarts. Turn off the computer and di

Página 49 - IDE Redirection

2. Type admin in the Intel ME Passwordfield.Press<Enter>. Passwords are case sensitive. You must change the default password before making

Página 50

5. The following message appears: System resets after configuration change. Continue (Y/N). Press <y>. 6. Intel ME State Control is the nex

Página 51 -  

7. Select Intel ME Firmware Local Update.Press<Enter>. 8. Select Disabled. Press <Enter>. The default setting for this option is Dis

Página 52 - SMB Mode

10. Manageability Feature Selection is the next option. This feature sets the platform management mode. The default setting is Intel AMT. Selecting

Página 53

12. Select Intel ME Power Control. Press <Enter>.  13. Intel ME ON in Host Sleep States is the next option. The default setting is Mobile:

Página 54

14. Select Return to Previous Menu. Press <Enter>. 15. Select Return to Previous Menu. Press <Enter>. 16. Exit the MEBx Setup and sa

Página 55

 4. Select Host Name.Press<Enter>. 5. Then type in a unique name for this Intel AMT machine. Press <Enter>. Spaces are not accepte

Página 56

Always Open qualifies the override counter and allows local ME firmware updates. The override counter is a value set in the factory that, by default,

Página 57

 l [DHCP Enable] Disable DHCP (Y/N) Press <n>.  l Domain Name Type the domain name into the field.

Página 58

8. Select Provision Model from the menu. Press <Enter>. 9. The following message appears: The following message appears: l Change to Intel A

Página 59

10. Skip the Un-Provision option. This option returns the computer to factory defaults. See Return to Default for more information about unprovision

Página 60

 l User name & Password Select Enabled and then press <Enter>. This option allows you to add users and passwords from the WebGUI. If the o

Página 61

 l IDE Redirection Select Enabled and then press <Enter>. 13. Secure Firmware Update is the next option. The default setting is Enabled.

Página 62

14. Skip Set PRTC. 15. Idle Timeout is the next option. The default setting is 1. This timeout is applicable only when a WoL option is selected i

Página 63

16. Select Return to Previous Menu. Press <Enter>. 17. Select Exit. Press <Enter>.

Página 64

18. The following message appears: Are you sure you want to exit? (Y/N): Press <y>. 19. The computer restarts. Turn off the computer and di

Página 65

Back to Contents Page Troubleshooting Dell™ Systems Management Administrator's Guide Return to Default (Un-Provisioning) Firmware Flash Seria

Página 66

Back to Contents Page Using the Intel® AMT WebGUI Dell™ Systems Management Administrator's Guide The Intel® AMT WebGUI is a Web browser-based in

Página 67

Intel ME Features Control The ME Features Control menu contains the following configuration selection. Manageability Feature Selection When you se

Página 68 - Troubleshooting

When you change the option from Intel AMT to None, a warning that Intel AMT un-provisions automatically if you accept the change appears. The None opt

Página 69 - AMT WebGUI

The Intel AMT Configuration page contains the user-configurable options listed below. For images of these menu options, see Enterprise Mode and SMB M

Comentários a estes Manuais

Sem comentários