Dell Micrsoft Hyper-V Server 2008 Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 22
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
Implementing SharePoint Server 2010 on Dell vStart Solution - A Reference Architecture for a
SharePoint Server 2010 farm on vStart 100 Hyper-V Solution
15
VLAN name
Virtual switch name
Purpose
Virtual machine
mapping
VLAN_F_DB_Cluster
vSwitch#2
Used by SQL DB servers
in the SharePoint farm
for the SQL failover
cluster private
communication.
DB1 and DB2
VLAN_G_WFE_NLB
vSwitch#3
Used by WFE servers in
the SharePoint farm for
the NLB cluster
communication.
WFE1 and WFE2
The VLAN segregation for the different network types helps isolate the traffic among components of
the SharePoint farm. Also, as an application best practice, all the SharePoint 2010 farm roles on any of
the three Hyper-V cluster hosts communicate using the same virtual switch vSwitch#1 in this
architecture.
SAN architecture
The SAN includes two PowerConnect 7048 switches that support iSCSI data traffic. The two switches
were connected together with stacking modules in Ethernet mode configured as an inter-switch link
(ISL) Link Aggregation Group (LAG). In addition, the solution supports up to eight 1 GB uplinks from
each switch to link into an existing core iSCSI network infrastructure.
Similar to the LAN traffic, the traffic for the SAN was also segregated into its own VLAN. This facilitates
isolation from the default VLAN and gives a separation between SAN traffic and any other traffic that it
may come across if the SAN is uplinked to a LAN or extended to another SAN for replication.
In this reference architecture, there was only one VLAN created for iSCSI traffic. This includes both the
Hyper-V CSV cluster traffic to the iSCSI storage arrays and all the SharePoint Database access traffic.
A combination of NDC and add-in NIC ports was used for the iSCSI traffic and MPIO along with
EqualLogic Device Specific Module (DSM) is used for load balancing the iSCSI traffic. It also enables
fault tolerance against any physical link failures at either NDC or the add-in NIC.
Vista de página 14