Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guia do Utilizador Página 205

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 834
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 204
Thermal Group 207
Cooling Device Upper Nonrecoverable Threshold
Cooling Device Upper Critical Threshold
Cooling Device Upper Noncritical Threshold
Cooling Device Lower Noncritical Threshold
Name coolingDeviceUppernonrecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9
Description Defines the value of the fan’s upper nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only
Name coolingDeviceUpperCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10
Description Defines the value of the fan’s upper critical threshold.
Syntax DellSigned32BitRange
Access Read-only
Name coolingDeviceUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.11
Description Defines the user-assigned value of the fan’s upper noncritical
threshold.
Syntax DellSigned32BitRange
Access Read-write
Name coolingDeviceLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.12
Description Defines the user-assigned value of the fan’s lower noncritical
threshold.
Syntax DellSigned32BitRange
Access Read-write
book.book Page 207 Wednesday, March 6, 2013 12:37 AM
Vista de página 204
1 2 ... 200 201 202 203 204 205 206 207 208 209 210 ... 833 834

Comentários a estes Manuais

Sem comentários