Dell™ Systems Management Administrator's Guide Notes, Notices, and Cautions Information in this document is subject to change without notice.
This allows you to select between small business and enterprise mode. Enterprise mode may have different security settings than small business mode. B
l Username and Password – DISABLED** / ENABLED This option provides the user authentication for SOL/IDER session. If the Kerberos protocol is used,
Idle Timeout Use this setting to define the ME WoL idle timeout. When this timer expires, the ME enters a low-power state. This timeout takes effect
Save and exit MEBx and then boot the computer to the Microsoft®Windows®operating system. Intel AMT in Static Mode Settings Example The table below
*Default setting **May cause Intel AMT partial unprovision 1 Intel ME Platform State Control is only changed for Management Engine (ME) troubleshootin
Back to Contents Page About Intel® Active Management Technology Dell™ Systems Management Administrator's Guide Intel® Active Management Technolo
Back to Contents Page Redirecting Serial and IDE Communications Dell™ Systems Management Administrator's Guide Intel® AMT makes it possible to r
Back to Contents Page Intel® AMT Setup and Configuration Overview Dell™ Systems Management Administrator's Guide Terms Setup and Configuration
Back to Contents Page Provisioning: Completing the Setup and Configuration Process Dell™ Systems Management Administrator's Guide Using a Confi
Setup and Configuration Using a USB Storage Device 1. Format a USB device with the FAT16 file system and no volume label and then set it aside.
Back to Contents Page Deployment Dell™ Systems Management Administrator's Guide Once you are ready to deploy a computer to a user, plug the comp
5. Click the plus (+) to expand the Section 1. Provisioning section. 6. Click the plus (+) to expand the Basic Provisioning (without TLS) section.
7. Select Step 1. Configure DNS. The notification server with an out-of-band management solution installed must be registered in DNS as "Provis
The IP address for the ProvisionServer and Intel SCS are now visible. 9. Select Step 2. Discovery Capabilities.
10. Verify that the setting is Enabled. If Disabled, click the checkbox next to Disabled and click Apply. 11. Select Step 3. View Intel AMT Capable
Any Intel AMT capable computers on the network are visible in this list. 12. Select Step 4. Create Profile.
13. Click the plus (+) to add a new profile. 14. On the General tab the administrator can modify the profile name, description, and password. The a
15. The Network tab provides the option to enable ping responses, VLAN, WebUI, Serial over LAN, and IDE Redirection. If you are configuring Intel AM
18. The Power Policy tab has configuration options to select the sleep states for Intel AMT and an Idle Timeout setting. It is recommended that Idle
20. Select the icon with the arrow pointing out to Export Security Keys to USB Key. 21. Select the Generate keys before export radio button.
22. Enter the number of keys to generate (depends on the number of computers that need to be provisioned). The default is 50. 23. The Intel ME defa
Back to Contents Page Intel® Management Engine BIOS Extension (MEBx) Dell™ Systems Management Administrator's Guide Intel MEBx Overview Config
24. Click Generate. Once the keys have been created, a link appears to the left of the Generate button. 25. Insert the previously formatted USB devi
c. Click Close in the Download complete dialog box. The setup.bin file is now visible in the drive explorer window. 27. Close the Export Security
30. Press any key to continue with system boot... 31. Once complete, turn off the computer and move back to the management server. 32. Select Ste
34. Select Step 7. Monitor Provisioning Process. The computers for which the keys were applied begin to appearing in the system list. At first the
35. Select Step 8. Monitor Profile Assignments. The computers for which profiles were assigned appear in the list. Each computer is identified by t
Once the computers are provisioned, they are visible under the Collections folder in All configured Intel AMT computers. Using MEBx Interface to Co
Intel AMT Configuration sets up all other Intel AMT options not covered in Intel AMT Setup, such as enabling the computer for Serial-Over-LAN (SOL) or
3. Select Change Intel ME Password. Press <Enter>. Type the new password twice for verification. The new password must include the followin
5. The following message appears: System resets after configuration change. Continue (Y/N). Press <y>. 6. Intel ME State Control is the ne
7. Select Intel ME Firmware Local Update. Press <Enter>. 8. Select Always Open. Press <Enter>. The default setting for this option is D
The new password must include the following elements: l Eight characters l One uppercase letter l One lowercase letter l A number l A special (non
10. Manageability Feature Selection is the next option. This feature sets the platform management mode. The default setting is Intel AMT. Selectin
12. Select Intel ME Power Control. Press <Enter>. 13. Intel ME ON in Host Sleep States is the next option. The default setting is Mobile:
14. Select Return to Previous Menu. Press <Enter>. 15. Select Return to Previous Menu. Press <Enter>. 16. Exit the MEBx Setup and sa
4. Select Host Name. Press <Enter>. Then type in a unique name for this Intel AMT machine. Press <Enter>. Spaces are not accepted in
l [DHCP Enable] Disable DHCP (Y/N) Press <n>. l Domain Name Type the domain name into the field.
6. Select Provision Server from the menu. Press <Enter>. 7. Type the provisioning server IP in the Provisioning server address field and pr
8. Type the port in the Port number field and press <ENTER>. The following message appears: l [Intel (R) AMT 2.6 Mode] [Enterprise]
10. Select SOL/IDE-R. Press <Enter>. 11. The following messages appear, and require the response indicated in the following bulleted list
l User name & Password ¡ Select Enabled and then press <Enter>. This option allows you to add users and passwords from the WebGUI. If t
l IDE Redirection Select Enabled and then press <Enter>. 12. Secure Firmware Update is the next option. The default setting is Enabled.
When enabled, the ME State Control option lets you disable ME to isolate the ME computer from the main platform while debugging a field malfunction.
13. Skip Set PRTC. 14. Idle Timeout is the next option. The default setting is 1. This timeout is applicable only when a WoL option is selected i
15. Select Return to Previous Menu. Press <Enter>. 16. Select Exit. Press <Enter>.
17. The following message appears: Are you sure you want to exit? (Y/N): Press <y>. 18. The computer restarts. Turn off the computer and di
2. Type admin in the Intel ME Passwordfield.Press<Enter>. Passwords are case sensitive. You must change the default password before making
5. The following message appears: System resets after configuration change. Continue (Y/N). Press <y>. 6. Intel ME State Control is the nex
7. Select Intel ME Firmware Local Update.Press<Enter>. 8. Select Disabled. Press <Enter>. The default setting for this option is Dis
10. Manageability Feature Selection is the next option. This feature sets the platform management mode. The default setting is Intel AMT. Selecting
12. Select Intel ME Power Control. Press <Enter>. 13. Intel ME ON in Host Sleep States is the next option. The default setting is Mobile:
14. Select Return to Previous Menu. Press <Enter>. 15. Select Return to Previous Menu. Press <Enter>. 16. Exit the MEBx Setup and sa
4. Select Host Name.Press<Enter>. 5. Then type in a unique name for this Intel AMT machine. Press <Enter>. Spaces are not accepte
Always Open qualifies the override counter and allows local ME firmware updates. The override counter is a value set in the factory that, by default,
l [DHCP Enable] Disable DHCP (Y/N) Press <n>. l Domain Name Type the domain name into the field.
8. Select Provision Model from the menu. Press <Enter>. 9. The following message appears: The following message appears: l Change to Intel A
10. Skip the Un-Provision option. This option returns the computer to factory defaults. See Return to Default for more information about unprovision
l User name & Password Select Enabled and then press <Enter>. This option allows you to add users and passwords from the WebGUI. If the o
l IDE Redirection Select Enabled and then press <Enter>. 13. Secure Firmware Update is the next option. The default setting is Enabled.
14. Skip Set PRTC. 15. Idle Timeout is the next option. The default setting is 1. This timeout is applicable only when a WoL option is selected i
16. Select Return to Previous Menu. Press <Enter>. 17. Select Exit. Press <Enter>.
18. The following message appears: Are you sure you want to exit? (Y/N): Press <y>. 19. The computer restarts. Turn off the computer and di
Back to Contents Page Troubleshooting Dell™ Systems Management Administrator's Guide Return to Default (Un-Provisioning) Firmware Flash Seria
Back to Contents Page Using the Intel® AMT WebGUI Dell™ Systems Management Administrator's Guide The Intel® AMT WebGUI is a Web browser-based in
Intel ME Features Control The ME Features Control menu contains the following configuration selection. Manageability Feature Selection When you se
When you change the option from Intel AMT to None, a warning that Intel AMT un-provisions automatically if you accept the change appears. The None opt
The Intel AMT Configuration page contains the user-configurable options listed below. For images of these menu options, see Enterprise Mode and SMB M
Comentários a estes Manuais