CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.8 OCTOBER 15, 2014 WWW.CISCO.COMSpec SheetCisco UCS C240 M4High-Densi

Página 2 - CONTENTS

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)10BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER STANDARD CA

Página 3

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)BASE SERVER STANDARD CAPABILITIES and FEATURES11Internal storage device

Página 4

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)12BASE SERVER STANDARD CAPABILITIES and FEATURESStorage controller E

Página 5 - OVERVIEW

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)BASE SERVER STANDARD CAPABILITIES and FEATURES13Modular LAN on Motherbo

Página 6 - DETAILED VIEWS

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)14CONFIGURING the SERVERCONFIGURING the SERVERFollow these steps to con

Página 7

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER15STEP 1 VERIFY SERVER SKUSelect one server produ

Página 8

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)16CONFIGURING the SERVERSTEP 2 SELECT RISER CARDS (OPTIONAL)There are t

Página 9 - Chassis Rear View

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER17STEP 3 SELECT CPU(s)The standard CPU features a

Página 10

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)18CONFIGURING the SERVERApproved Configurations(1) 1-CPU configurations

Página 11

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER19STEP 4 SELECT MEMORYThe standard memory feature

Página 12 - 2. FBWC option

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)2CONTENTSOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 13 - Notes . .

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)20CONFIGURING the SERVERSelect DIMMs and Memory MirroringSelect the mem

Página 14 - CONFIGURING the SERVER

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER21(2) 1-CPU configuration with memory mirroring:

Página 15 - STEP 1 VERIFY SERVER SKU

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)22CONFIGURING the SERVER Select the memory mirroring option (N01-MMIRR

Página 16

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER23As a consequence, faster DIMMs will be operated

Página 17 - STEP 3 SELECT CPU(s)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)24CONFIGURING the SERVERSTEP 5 SELECT RAID CONFIGURATIONThe RAID contro

Página 18

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER25Select RAID OptionsSelect as follows (these cho

Página 19 - STEP 4 SELECT MEMORY

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)26CONFIGURING the SERVERTable 9 RAID Controller Options Product ID (P

Página 20

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER27Approved ConfigurationsThe C240 M4 SFF server c

Página 21

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)28CONFIGURING the SERVERSee Table 10 for a summary of the supported RAI

Página 22

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER29Caveats A maximum of one Cisco 12G SAS 9300-8e

Página 23

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)3Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . .

Página 24

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)30CONFIGURING the SERVERSTEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID

Página 25

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER31Enterprise Performance SSDs (high endurance, su

Página 26

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)32CONFIGURING the SERVERThe available boot drives are listed in Table 1

Página 27

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER33(2) Systems Using Boot Drives If you are confi

Página 28

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)34CONFIGURING the SERVERSTEP 7 SELECT PCIe OPTION CARD(s)The standard P

Página 29

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER35Caveats If you choose an external drives PCIe

Página 30

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)36CONFIGURING the SERVER— Only a single plug-in PCIe VIC card may be in

Página 31

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER37details. The quantity and type of PCIe cards t

Página 32

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)38CONFIGURING the SERVERSTEP 8 ORDER OPTIONAL NETWORK CARD ACCESSORIESC

Página 33

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER39Approved Configurations(1) Choose Up to Two SFP

Página 34

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)4CONTENTS

Página 35

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)40CONFIGURING the SERVERTable 17 PCIe Card Compatibility PCIe CardsT

Página 36 - ■ For 2-CPU systems:

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER41Figure 7 Network Card ConnectionsN2XX-AQPCI05

Página 37

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)42CONFIGURING the SERVERSTEP 9 ORDER GPU CARDS(OPTIONAL)Select GPU Opti

Página 38

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER43NOTE: See Figure 8 on page 62 for the location

Página 39

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)44CONFIGURING the SERVERSTEP 10 ORDER POWER SUPPLYThe C240 M4 server re

Página 40

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER45STEP 11 SELECT AC POWER CORD(s)Using Table 20,

Página 41

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)46CONFIGURING the SERVERSFS-250V-10A-AR Power Cord, SFS, 250V, 10A, Arg

Página 42 - 95°F (0° to 35°C)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER47CAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/V

Página 43

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)48CONFIGURING the SERVERSTEP 12 ORDER RAIL KIT AND OPTIONAL REVERSIBLE

Página 44 - STEP 10 ORDER POWER SUPPLY

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER49STEP 13 ORDER A TRUSTED PLATFORM MODULE (OPTION

Página 45

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)OVERVIEW5OVERVIEWThe UCS C240 M4 SFF server is the newest 2-socket, 2U

Página 46

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)50CONFIGURING the SERVERSTEP 14 ORDER CISCO FLEXIBLE FLASH SD CARD MODU

Página 47

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER51STEP 15 SELECT OPERATING SYSTEM AND VALUE-ADDED

Página 48 - MANAGEMENT ARM

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)52CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 So

Página 49

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER53VMware 5VMW-VS5-STD-1A VMware vSphere 5 Standar

Página 50 - ■ Do not mix SD card sizes

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)54CONFIGURING the SERVERSTEP 16 SELECT OPERATING SYSTEM MEDIA KITSelect

Página 51

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER55STEP 17 SELECT SERVICE and SUPPORT LEVELA varie

Página 52

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)56CONFIGURING the SERVERSMARTnet for UCS Hardware Only ServiceFor faste

Página 53

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER57See Table 30.Partner Support Service for UCS Ha

Página 54

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)58CONFIGURING the SERVERYou can choose a service listed in Table 32.Uni

Página 55

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER59For more service and support information, see t

Página 56

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)6DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows the 24-dr

Página 57

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)60OPTIONAL STEP - ORDER RACK(s)OPTIONAL STEP - ORDER RACK(s)The optiona

Página 58

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)OPTIONAL STEP - ORDER PDU61OPTIONAL STEP - ORDER PDUAn optional power d

Página 59

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)62SUPPLEMENTAL MATERIALSUPPLEMENTAL MATERIALCHASSISAn internal view of

Página 60 - OPTIONAL STEP - ORDER RACK(s)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL63CPUs and DIMMsPhysical LayoutEach CPU has four D

Página 61 - OPTIONAL STEP - ORDER PDU

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)64SUPPLEMENTAL MATERIALMemory Population Rules When considering the mem

Página 62 - SUPPLEMENTAL MATERIAL

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL65DIMM Population OrderPopulate the DIMMs for a CP

Página 63 - CPUs and DIMMs

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)66SUPPLEMENTAL MATERIALRecommended Memory ConfigurationThis section exp

Página 64 - Memory Population Rules

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL67Additional DIMM PopulationsThe list in Table 39

Página 65 - DIMM Population Order

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)68SUPPLEMENTAL MATERIALRAID DetailsThe available RAID configurations ar

Página 66

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL69RAID Option ROM (OPROM) SettingsThe server conta

Página 67 - Additional DIMM Populations

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)DETAILED VIEWS7Figure 3 shows the 16-drive Cisco UCS C240 M4 High-Densi

Página 68 - RAID Details

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)70SUPPLEMENTAL MATERIALRiser Card Configuration and OptionsThe three ri

Página 69

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL71Table 41 Riser Card 2 SlotsSlot # Height Length

Página 70

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)72SUPPLEMENTAL MATERIALEmbedded SATA RAID: Two SATA ControllersThe embe

Página 71

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL73To Create a RAID Group(1) While the server is bo

Página 72

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)74SUPPLEMENTAL MATERIAL(2) Press Ctrl+M to start the RAID group creatio

Página 73

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL75Serial Port DetailsThe pinout details of the rea

Página 74

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)76SUPPLEMENTAL MATERIALUpgrade and Servicing-Related PartsThis section

Página 75 - Serial Port Details

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL77Adding an Additional CPU (with CPU heat sink)All

Página 76

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)78SUPPLEMENTAL MATERIALAir Baffle Replacement KitAir baffles are design

Página 77 - Motherboard Lithium Battery

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL79RACKSThe Cisco R42610 rack (see Figure 16) is ce

Página 78 - CPU Heat Sink Cleaning Kit

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)8DETAILED VIEWSFigure 3 shows the 8-drive Cisco UCS C240 M4 High-Densit

Página 79

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)80SUPPLEMENTAL MATERIALFigure 16 Cisco R42610 RackFront view - door c

Página 80 - Figure 16 Cisco R42610 Rack

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL81PDUsCisco RP Series Power Distribution Units (PD

Página 81

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)82SUPPLEMENTAL MATERIALKVM CABLEThe KVM cable provides a connection int

Página 82 - KVM CABLE

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL83Motherboard USB and SD Ports, and RAID Card Back

Página 83

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)84TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions and Weight

Página 84 - TECHNICAL SPECIFICATIONS

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)TECHNICAL SPECIFICATIONS85Power SpecificationsThe server is available w

Página 85 - Power Specifications

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)86TECHNICAL SPECIFICATIONSTable 47 UCS C240 M4 SFF Power Specification

Página 86

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)87TECHNICAL SPECIFICATIONSFor configuration-specific power specificatio

Página 87

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)88TECHNICAL SPECIFICATIONSEnvironmental SpecificationsThe power specifi

Página 88 - Environmental Specifications

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)89TECHNICAL SPECIFICATIONSCompliance RequirementsThe regulatory complia

Página 89 - Compliance Requirements

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)DETAILED VIEWS9Chassis Rear ViewFigure 5 shows the external features of

Página 90

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)TECHNICAL SPECIFICATIONS90